MRSAS(4)               FreeBSD Kernel Interfaces Manual               MRSAS(4)

NAME

     mrsas - Broadcom/LSI MegaRAID 6/12Gb/s SAS+SATA RAID controller driver

SYNOPSIS

     device pci
     device mrsas

     In loader.conf(5):
     mrsas_load="YES"

     In sysctl.conf(5):
     dev.mrsas.X.disable_ocr
     dev.mrsas.X.fw_outstanding
     dev.mrsas.X.mrsas_fw_fault_check_delay
     dev.mrsas.X.mrsas_io_timeout
     hw.mrsas.X.debug_level

DESCRIPTION

     The mrsas driver will detect Broadcom/LSI's 6Gb/s and 12Gb/s PCI Express
     SAS/SATA/NVMe RAID controllers.  A disk (virtual disk/physical disk)
     attached to the mrsas driver will be visible to the user through
     camcontrol(8) as /dev/da? device nodes.  A simple management interface is
     also provided per-controller via the /dev/mrsas? device node.

     The mrsas name is derived from the phrase "MegaRAID SAS HBA", which is
     substantially different than the old "MegaRAID" Driver mfi(4) which does
     not connect targets to the cam(4) layer and thus requires a new driver
     which attaches targets to the cam(4) layer.  Older MegaRAID controllers
     are supported by mfi(4) and will not work with mrsas, but both the mfi(4)
     and mrsas drivers can detect and manage the Broadcom/LSI MegaRAID SAS
     2208/2308/3008/3108 series of controllers.

     The device.hints(5) option is provided to tune the mrsas driver's
     behavior for LSI MegaRAID SAS 2208/2308/3008/3108 controllers.  By
     default, the mfi(4) driver will detect these controllers.  See the
     PRIORITY section to know more about driver priority for MR-Fusion
     devices.

     mrsas will provide a priority of (-30) (between BUS_PROBE_DEFAULT and
     BUS_PROBE_LOW_PRIORITY) at probe call for device id's 0x005B, 0x005D, and
     0x005F so that mrsas does not take control of these devices without user
     intervention.

     Solid-state drives (SSD) get ATA TRIM support with mrsas if underlying
     adapter allows it.  This may require configuring SSD as Non-RAID drive
     rather then JBOD virtual mode.

HARDWARE

     The mrsas driver supports the following Broadcom/LSI SATA/SAS RAID
     controllers:

     Controller               Chip            Speed
     Broadcom SAS3916         Aero            12Gb/s
     Broadcom SAS3908         Aero            12Gb/s
     LSI MegaRAID SAS 9380    Invader/Fury    12Gb/s
     LSI MegaRAID SAS 9361    Invader/Fury    12Gb/s
     LSI MegaRAID SAS 9341    Invader/Fury    12Gb/s
     LSI MegaRAID SAS 9286    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9285    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9272    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9271    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9270    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9267    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9266    Thunderbolt     6Gb/s
     LSI MegaRAID SAS 9265    Thunderbolt     6Gb/s
     LSI SAS 3108                             12Gb/s
     LSI SAS 3008                             12Gb/s
     LSI SAS 2308                             6Gb/s
     LSI SAS 2208                             6Gb/s
     DELL PERC H830           Invader/Fury    12Gb/s
     DELL PERC H810           Thunderbolt     6Gb/s
     DELL PERC H730/P         Invader/Fury    12Gb/s
     DELL PERC H710/P         Thunderbolt     6Gb/s
     DELL PERC H330           Invader/Fury    12Gb/s
     Fujitsu D3116            Thunderbolt     6Gb/s

CONFIGURATION

     To disable Online Controller Reset(OCR) for a specific mrsas driver
     instance, set the following tunable value in loader.conf(5):

           dev.mrsas.X.disable_ocr=1

     where X is the adapter number.

     To change the I/O timeout value for a specific mrsas driver instance, set
     the following tunable value in loader.conf(5):

           dev.mrsas.X.mrsas_io_timeout=NNNNNN

     where NNNNNN is the timeout value in milli-seconds.

     To change the firmware fault check timer value for a specific mrsas
     driver instance, set the following tunable value in loader.conf(5):

           dev.mrsas.X.mrsas_fw_fault_check_delay=NN

     where NN is the fault check delay value in seconds.

     The current number of active I/O commands is shown in the
     dev.mrsas.X.fw_outstanding sysctl(8) variable.

DEBUGGING

     To enable debugging prints from the mrsas driver, set the
     hw.mrsas.X.debug_level variable, where X is the adapter number, either in
     loader.conf(5) or via sysctl(8).  The following bits have the described
     effects:

           0x01    Enable informational prints.

           0x02    Enable tracing prints.

           0x04    Enable prints for driver faults.

           0x08    Enable prints for OCR and I/O timeout.

           0x10    Enable prints for AEN events.

PRIORITY

     The mrsas driver will always set a default (-30) priority in the PCI
     subsystem for selection of MR-Fusion cards.  (It is between
     BUS_PROBE_DEFAULT and BUS_PROBE_LOW_PRIORITY).  MR-Fusion Controllers
     include all cards with the Device IDs - 0x005B, 0x005D, 0x005F.

     The mfi(4) driver will set a priority of either BUS_PROBE_DEFAULT or
     BUS_PROBE_LOW_PRIORITY (depending on the device.hints setting) in the PCI
     subsystem for selection of MR-Fusion cards.  With the above design in
     place, the mfi(4) driver will attach to a MR-Fusion card given that it
     has a higher priority than mrsas.

     Using /boot/device.hints (as mentioned below), the user can provide a
     preference for the mrsas driver to detect a MR-Fusion card instead of the
     mfi(4) driver.

           hw.mfi.mrsas_enable="1"

     At boot time, the mfi(4) driver will get priority to detect MR-Fusion
     controllers by default.  Before changing this default driver selection
     policy, LSI advises users to understand how the driver selection policy
     works.  LSI's policy is to provide priority to the mfi(4) driver to
     detect MR-Fusion cards, but allow for the ability to choose the mrsas
     driver to detect MR-Fusion cards.

     LSI recommends setting hw.mfi.mrsas_enable="0" for customers who are
     using the older mfi(4) driver and do not want to switch to mrsas.  For
     those using a MR-Fusion controller for the first time, LSI recommends
     using the mrsas driver and setting hw.mfi.mrsas_enable="1".

     Changing the default behavior is well tested under most conditions, but
     unexpected behavior may pop up if more complex and unrealistic operations
     are executed by switching between the mfi(4) and mrsas drivers for MR-
     Fusion.  Switching drivers is designed to happen only one time.  Although
     multiple switching is possible, it is not recommended.  The user should
     decide from boot which driver they want to use for the MR-Fusion card.

     The user may see different device names when switching from mfi(4) to
     mrsas.  This behavior works as intended and the user needs to change the
     fstab(5) entry manually if they are doing any experiments with mfi(4) and
     mrsas interoperability.

FILES

     /dev/da?     array/logical disk interface
     /dev/mrsas?  management interface

SEE ALSO

     cam(4), mfi(4), pci(4), device.hints(5), camcontrol(8)

HISTORY

     The mrsas driver first appeared in FreeBSD 10.1.

     mfi Driver: mfi(4) is the old FreeBSD driver which started with support
     for Gen-1 Controllers and was extended to support up to MR-Fusion (Device
     ID = 0x005B, 0x005D, 0x005F).

     mrsas Driver: mrsas is the new driver reworked by LSI which supports
     Thunderbolt and onward products.  The SAS+SATA RAID controller with
     device id 0x005B is referred to as the Thunderbolt controller throughout
     this man page.

     cam aware HBA drivers: FreeBSD has a cam(4) layer which attaches storage
     devices and provides a common access mechanism to storage controllers and
     attached devices.  The mrsas driver is cam(4) aware and devices
     associated with mrsas can be seen using camcontrol(8).  The mfi(4) driver
     does not understand the cam(4) layer and it directly associates storage
     disks to the block layer.

     Thunderbolt Controller: This is the 6Gb/s MegaRAID HBA card which has
     device id 0x005B.

     Invader Controller: This is 12Gb/s MegaRAID HBA card which has device id
     0x005D.

     Fury Controller: This is the 12Gb/s MegaRAID HBA card which has device id
     0x005F.

AUTHORS

     The mrsas driver and this manual page were written by Kashyap Desai
     <Kashyap.Desai@lsi.com>.

CAVEATS

     The mrsas driver exposes devices as /dev/da?, whereas mfi(4) exposes
     devices as /dev/mfid?.

     mrsas does not support the Linux Emulator Interface, mfiutil(8), or
     device name aliases for switching drivers without editing fstab(5).

FreeBSD 15.1-STABLE-HBSD         May 23, 2026                         MRSAS(4)